DESCRIPTION The sampling capsule, screwed onto the end of the dip-pipe, is introduced into the reactor at the required depth. The PTFE flanges, set with the o'ring, ensure the tightness of the dip-pipe. Even when the ball valve is opened, the reactor can stay under pressure or under vacuum. The sample is extracted by activating the piston. A wash solvent cleans the dip-pipe when it is removed from the reactor. Before the dip-pipe is fully with-drawn, the ball valve is closed. The sampling capsule filled with liquid is unscrewed and brought to the laboratory. Sampling capsule with piston and compensation plug. |
PTFE Flanges with inside o'ring for guiding and cleaning the dip-pipe and sampling capsule. |
Introduction of the sampling capsule through the PTFE flanges connected to the cleaning and recovering system. |
AUTOMATIC
![]() |
Automatic :
The system is fully automatic. The top of the dip-pipe is connected to a driving belt which moves up and down. The belt and on/off ball valve are operated pneumatically. |
MAXI WORKING CONDITIONS |
IN THE REACTOR : |
MANUAL : +0,3 bar / -0,5 bar and 120°C, 4,35 psig / -7,25 psig and 248°F |
AUTOMATIC : +3 bar / -0,5 bar and 150°C, 43,5 psig / -7,25 psig and 302°F |
![]() |
Sampling capsule | Dimension "C" | Dimension "D" |
25 cc |
161 mm/6,3" |
238 mm/3,35" |
|
50 cc |
227 mm/8,9" |
304 mm/11,95" |
|
75 cc |
292 mm/11,5" |
369 mm/14,5" |
|
100 cc |
358 mm/14,1" |
435 mm/17,1" |
|
125 cc |
422 mm/16,6" |
499 mm/19,65" |
|
150 cc |
489 mm/19,25" |
566 mm/22,3" |
DIP-PIPE AND SAMPLING CAPSULE * |
O'RING * |
SAMPLING CAPSULE VOLUME |
MAXI SAMPLING DEPTH ACCORDING TO CAPSULE SIZES (DIMENSION A) |
STAINLESS STEEL 316L |
FPM |
25 cc |
2,95 m/116,15" |
ALLOY C22 |
PTFE |
50 cc |
2,88 m/113,40" |
TITANE |
KALREZ (R) |
75 cc |
2,82 m/111,02" |
FFKM |
100 cc |
2,75 m/108,26" |
|
SILICONE FLUORE |
125 cc |
2,69 m/105,90" |
|
150 cc |
2,62 m/103,15" |
* OTHERS MATERIALS ON REQUEST